Allen-Bradley 140M-C2E-B63 Ser. C Motor Starter

  • Sale
  • Regular price $29.00


    • Rated short-circuit breaking capacity lcu at 400 V, AC: 100 kA
    • Rated operation power at AC-3, 400 V: 2 kW
    • Rated operation power at AC-3, 230 V: 5 kW
    • Rated operating voltage: 3 A
    • Type of control element: Turn button
    • Overload release current setting: 4 A
    • Type of electrical connection of main circuit: Screw connection
    • Magnetic release current per IEC: 82 A
    • Rated operational current (Ie) per IEC: 3 A
    • Magnetic trip current: 82 A
    • Short circuit current (Type 2 coordination), max-inv: 50 kA @ 480V
    • Current range: ..6.3 A
    • Ultimate short circuit breaking capacity (Icu) per IEC: 4 kA @ 690V
    • Rated service short circuit breaking capacity (Ics) per IEC: 4 kA @ 690V
    • Hp rating, max: 5 Hp @ 575V, 3-phase
    • Rated operating voltage, max: 690V per IEC, SEV, VDE0660
    • Electrical life cycle: (Ie max.) 100000 operations
    • Short circuit current for combination motor controller with 100-K contactor, max-inv: 65 kA @ 480Y/277V, UL 508-Type F
    • Short circuit current for combination motor controller with 100-C contactor, max-inv: 65 kA @ 480Y/277V, UL 508-Type F
    • Short circuit current for self-protected combination motor controller with 100-C contactor, max-inv: 65 kA @ 480Y/277V, UL 508-Type E
    • Switching of standard motors per IEC: 0 kW @ 690V, 3-phase
    • KW rating, max: 4 kW @ 690V (AC-3), 3-phase
    • Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC: No back-up fuse required @ 500V
    • Short circuit current for group motor installation with 100-K contactor, max-inv: 65 kA @ 480V, UL 508-manual motor controller
    • Short circuit current for motor disconnect with 100-K contactor, max-inv: 65 kA @ 480V, UL 508-manual motor controller
    • Short circuit current for group motor installation with 100-C contactor, max-inv: 65 kA @ 480V, UL 508-manual motor controller
    • Short circuit current for motor disconnect with 100-C contactor, max-inv: 65 kA @ 480V, UL 508-manual motor controller
    • Rated thermal current: 1...32 A @ 60 °C ambient temperature (Ith)-inv
    • Short circuit current for tap conductor protection, max: 65 kA @ 480Y/277V per UL 508-manual motor controller
    • Short circuit current for combination motor controller, max: 65 kA @ 480V/277V per UL 508-self-protected (Type E)
    • Fuse or circuit breaker per NEC, max: 450 A, UL 508-manual motor controller
    • Fuse or circuit breaker rating per NEC, max: 450 A, UL 508-manual motor controller with 100-C contactor
    • Short circuit current for group motor installation, max: 65 kA @ 480V, UL 508-manual motor controller
    • Short circuit current for motor disconnect, max: 65 kA @ 480V, UL 508-manual motor controller
    • Magnetic release current: Fixed setting 13...14 x Ie max. Ie max. = maximum values of setting ranges, (±20 %)
    • Number of poles: 3
    • With thermal protection: Yes
    • Phase failure sensitive: Yes
    • Switch off technique: Thermomagnetic
    • Switching frequency, max: 25 ops/h
    • Trip class: 10
    • Rated frequency: 50/60 Hz
    • Rated supply current: 1 A
    • Total power loss (Pv) for circuit breaker at rated load operating temperature-inv: 6 W
    • Phase loss protection: Differential release
    • Fuse or circuit breaker rating with 100-K contactor per NEC, max: 450 A, UL 508-manual motor controller
    • Main circuits/overvoltage category: 6kV/III @ rated impulse withstand voltage (Uimp)
    • Auxiliary circuits/overvoltage category-inv: 6kV/III @ rated impulse withstand voltage (Uimp)